Observations(m) X Y Z Actual 102.003 99.999 -0.191 WLT Integrated Round 1 101.938 99.999 -0.193 Round 2 102.007 99.965 -0.192 Round 3 102.009 100.098 -0.195 WLT Not Integrated Round 4 101.060 100.538 -0.157 Round 5 101.125 100.572 -0.159 Round 6 101.115 100.472 -0.164 Table 3: Round Trip Observations (m) Analysis Scale Error - Analysis Scenario 1 - Tape Measure Comparison By analyzing the observations found in Table 1 above, scale error can be determined. To define scale error, the recorded distances were averaged to compute the mean observed side length of each cube. These averaged lengths were then compared against the design dimensions of the models in order to obtain an estimate of the model viewer's scale. Here it was found that on this device, the TCH platform projects models at a near perfect 1:1 scale, with an average error over the three models of just -0.03%. Please note that scale error is device dependent; the results shown here are specific to this XR10 device and the results may vary from user to user. 10 cm Cube 50cm Cube 1m Cube Model Scale 100.00% 100.00% 99.90% Scale Error 0.00% 0.00% -0.10% Average Scale Error -0.03% (+/- 0.06%) Table 4: Scale Error Calculation 10